Concrete Slab Beneath a Tank Re-levelled in Lyttelton

Sub-industry
Tank Farm
Problems
Earthquake Remediation
Location
Christchurch, NZ
Year
2012
Solutions
Slab Lifting
Technology
Deep Injection, Slab Lifting

Concrete Slab-on-ground Tank Re-levelled

Summary

Uretek Deep-Injection foundation treatment was used to raise and re-level slab-on-ground bitumen tanks at a tank farm in Lyttleton, near Christchurch. This was required to rectify earthquake damage.

Objectives

With a total floor area of approximately 64m2 requiring correction, the tank feet settlement was up to 95mm and and the slab settlement was also up to 95mm.

Solution

The requirement was to Deep-Inject compaction grout directly beneath the concrete slab of the affected structure to improve the bearing capacity of any poorly compacted soils, minimise the potential for further settlement, and lift the structure back as close to level as practical.Uretek Deep-Injection was applied at 12 locations at 1200mm to 1500mm centres, keeping well down under the external tank walls to minimise risk of further cracking. The correction required just one day.

The site work was completed promptly, and was efficient, working within the confined spaces between the bitumen tanks. Deep-Injection is not rigid and therefore did not transfer the load directly to a different stratum of soil and minimal extra weight was imposed on already stressed ground following correction.

The sunken concrete slabs and the tanks were raised and re-levelled by Uretek Slab-Lifting, with the Deep- Injection increasing the bearing capacity of the sub- grade soil.

The team worked closely with the client’s engineers to document this work and complete the work according to the engineer’s specifications.

Resources

Download a pdf version of this project here

House Floor Raised and Re-levelled
Next Project

Large Building Re-levelled by JOG & UDI

Mainmark

© 2025 The Mainmark group of companies. ‘Mainmark®’, ‘Terefil®’, ‘Terefirm®’ and ‘Teretek®’ are trademarks of the Mainmark group of companies.

Mainmark Ground Engineering (NZ) Ltd

ISO 9001
ISO 14001
ISO 45001

Solutions

Ground Improvement

Subsidence Repair

Re-Levelling

Void Filling

Slab Lifting

Crack Wall Repairs

Sinking Floor and Slab Repair

Sinking Foundation Repair

Underpinning

Soil Replacement

Specialties

Commercial

Residential

Seismic

Technologies

Teretek®

Terefil®

JOG

About Us

Our team

Careers

Media & Press

News

Awards

Contact

Locations
Mainmark Auckland

50 Parkway Drive, Rosedale, Auckland 0632

 

Mainmark Christchurch

2 Baigent Way, Middleton, Christchurch 8024

Privacy Policy

Terms and Conditions

Created by Codex

Facebook